Tag Archives: motor and reducer

China Custom High Effciency and High Voltage AC Asynchronous Squirrel Cage Induction Electric Motor for Water Pump, Air Compreesor, Gear Reducer Fan Blower (Y2/YE3 Series) vacuum pump engine

Product Description

Why choose us ?
ELECTRIC MOTOR FEATURES  

Electric motor frame from 56 – 355, output range from 0.17HP to 430HP

Motor mounting type B3 (IM 1001), B35 (IM 2001), B5 (IM 3001), B14 (IM 3601), B34 (IM 2101)

Optional voltage 110V, 120V, 220V, 240V, 220/380V, 230V/400V, 380V/660V, 50HZ or 60HZ

Protection type IP44, IP54, IP55 on request 

Multiple mounting arrangement for optional           
Aluminum frame, end shields and base    

Strong cast iron frame
High strength cable
Shaft key and protector supplied        
Superior paint finish         
45# steel shaft and stainless steel shaft is optional
Electric motor continuous duty S1,S4
Electric motor have vacuum impregnation for insulation
Electric motor is class F insulation and class H insulation is optional
Electric motor has been make according to ISO9001, CE, UL, CCC, GS request

All of our products are make according to GOST, RoHS and IEC standard.

High performance and IE1, IE2, IE3 efficiency  

 

OUR ELECRIC MOTOR FOR CUSTOMER BENEFITS

Electricity saving and quiet operation
Electric motor can withstand water, dust and vermin
Electric motor very easy installation
Electric motor dependable Corrosion resistant and long life to work
Reliability performance and very competitive price.
 

HOW TO MAKE MOTOR ON CHINAMFG COMPANY

1. Silicon steel DR510, 800, 600, 360 standard use stamping of lamination stator and rotor die-casting

2. 100% copper winding and inserting stator (manual and semi-automatically)

3. Stator Vacuum impregnation and drying

4. CNC machining motor shaft, frame, end shields, etc

5. Professional workman inspecting spare parts every processing

6. Electric motor assembly product line

7. Electric motor will 100% test before painting.

8. Electric motor spray-paint on motor painting product line

9. Electric motor will 100% check again before packing.

An electric motor from material to finish motor, must pass 15 time check, and 100% testing, output power, voltage, electric current, non-load, 50% load, 75% load, 100% load and check the nameplate, packing. Finally shipping to our customer.

Att:Our company price was based on high height cold rolled steel stator to promise the efficiency ,if you need to cheaper ,you can choose short height stator or hot cold rolled steel stator ,thankyou

Product details 

YE3 PARAMETERS

SYNCHRONOUS OUTPUT SPEED=3000RPM     FREQUENCY=50HZ  VOLTAGE=380V 

MODEL

POWER 

(KW)

CURRENT 

(A)

SPEED  

(RPM)

EFF

POWER 

FACTOR

RATED 

TORQUE

TST IST TMAX

NOISE 

dB(A)

YE3-63M1-2 0.18kw 0.53 2720 63.9 0.8 0.63 2.2 5.5 2.2 61
YE3-63M2-2 0.25kw 0.7 2720 97.1 0.81 0.88 2.2 5.5 2.2 61
YE3-71M1-2 0.37kw 1 2740 69 0.81 1.29 2.2 6.1 2.2 62
YE3-71M2-2 0.55kw 1.4 2740 72.3 0.82 1.92 2.2 6.1 2.2 62
YE3-801-2 0.75kw 1.8 2830 80.7 0.83 2.5 2.2 7 2.3 62
YE3-802-2 1.1kw 2.5 2840 82.7 0.83 3.65 2.2 7.3 2.3 62
YE3-90S-2 1.5kw 3.4 2840 84.2 0.84 4.97 2.2 7.6 2.3 67
YE3-90L-2 2.2kw 4.8 2840 85.9 0.85 7.3 2.2 7.6 2.3 67
YE3-100L-2 3kw 6.3 2870 87.1 0.87 9.95 2.2 7.8 2.3 74
YE3-112M-2 4kw 8.2 2890 88.1 0.88 13.1 2.2 8.3 2.3 77
YE3-132S1-2 5.5kw 11.1 2900 89.2 0.88 17.9 2 8.3 2.3 79
YE3-132S2-2 7.5kw 15 2900 90.1 0.89 24.4 2 7.9 2.3 79
YE3-160M1-2 11kw 21.3 2930 912 0.89 35.6 2 8.1 2.3 81
YE3-160M2-2 15kw 28.7 2930 91.9 0.89 48.6 2 8.1 2.3 81
YE3-160L-2 18.5kw 34.7 2930 92.4 0.89 60 2 8.2 2.3 81
YE3–180M-2 22kw 41.2 2940 92.7 0.89 71.2 2 8.2 2.3 83
YE3-200-L1-2 30kw 55.3 2950 93.3 0.89 96.6 2 7.6 2.3 84
YE3-200L2-2 37kw 67.9 2950 93.7 0.89 119 2 7.6 2.3 84
YE3-225M-2 45kw 82.1 2970 94 0.89 145 2 7.7 2.3 86
YE3-250M-2 55kw 100.1 2970 94.3 0.89 177 2 7.7 2.3 89
YE3-280S-2 75kw 134 2970 94.7 0.89 241 1.8 7.1 2.3 91
YE3-280M-2 90kw 160.2 2970 95 0.89 289 1.8 7.1 2.3 91

SYNCHRONOUS OUTPUT SPEED=1500RPM     FREQUENCY=50HZ  VOLTAGE=380V

MODEL

POWER 

(KW)

CURRENT 

(A)

SPEED 

(RPM)

EFF

POWER 

FACTOR

RATED 

TORQUE

TST IST TMAX

NOISE 

dB(A)

YE3-63M1-4 0.12kw 0.45 1310rpm 55.8 0.72 0.87 2.1 4.4 2.2 52
YE3-63M2-4 0.18kw 0.64 1310rpm 58.6 0.73 1.31 2.1 4.4 2.2 52
YE3-71M1-4 0.25kw 0.81 1330rpm 63.6 0.74 1.8 2.1 5.2 2.2 55
YE3-71M2-4 0.37kw 1.1 1330rpm 65.3 0.75 2.66 2.1 5.2 2.2 55
YE3-801-4 0.55kw 1.4 1390rpm 80.6 0.75 3.67 2.3 6.5 2.3 56
YE3-8002-4 0.75kw 1.9 1390rpm 82.5 0.75 5.01 2.3 6.6 2.3 56
YE3-90S-4 1.1kw 2.7 1400rpm 84.1 0.76 7.35 2.3 6.8 2.3 59
YE3-90L-4 1.5kw 3.6 1400rpm 85.3 0.77 10 2.3 7 2.3 59
YE3-100L1-4 2.2kw 4.8 1430rpm 86.7 0.81 14.6 2.3 7.6 2.3 64
YE3-100L2-4 3kw 6.6 1430rpm 87.7 0.82 19.9 2.3 7.6 2.3 64
YE3-112M-4 4kw 8.6 1440rpm 88.6 0.82 26.3 2.2 7.8 2.3 65
YE3-132S-4 5.5kw 11.6 1440rpm 89.6 0.83 35.9 2 7.9 2.3 71
YE3-132M-4 7.5kw 14.6 1440rpm 90.4 0.84 48.9 2 7.5 2.3 71
YE3-160M-4 11kw 22.6 1460rpm 91.4 0.85 71.5 2 7.7 2.3 73
YE3-160L-4 15kw 29.3 1460rpm 92.1 0.86 97.4 2 7.8 2.3 73
YE3-180M-4 18.5kw 35.45 1470rpm 92.6 0.86 120 2 7.8 2.3 76
YE3-180L-4 22kw 42.35 1470rpm 93 0.86 143 2 7.8 2.3 76
YE3-200L-4 30kw 57.6 1475rpm 93.6 0.86 194 2 7.3 2.3 76
YE3-225S-4 37kw 69.8 1480rpm 93.9 0.86 239 2 7.4 2.3 78
YE3-225M-4 45kw 84.5 1480rpm 94.2 0.86 290 2 7.4 2.3 78
YE3-250M-4 55kw 103.1 1485rpm 94.6 0.86 354 2 7.4 2.3 79
YE3-280S-4 75kw 139.7 1490rpm 95 0.88 481 2 6.7 2.3 80
YE3-280M-4 90kw 166.9 1485rpm 95.2 0.88 577 2 6.9 2.3 80

SYNCHRONOUS OUTPUT SPEED=1000RPM     FREQUENCY=50HZ  VOLTAGE=380V

MODEL

POWER 

(KW)

CURRENT 

(A)

SPEED 

(RPM)

EFF

POWER 

FACTOR

RATED 

TORQUE

TST IST TMAX

NOISE 

dB(A)

YE3-71M1-6 0.18kw 0.76 850rpm 54.6 0.66 2.02 1.9 4 2 52
YE3-71M2-6 0.25kw 0.97 850rpm 57.4 0.68 2.81 1.9 4 2 52
YE3-80M1-6 0.37kw 1.2 890rpm 68 0.7 3.88 1.9 5.5 2.1 54
YE3-80M2-6 0.55kw 1.7 890rpm 72 0.71 5.68 1.9 5.8 2.1 54
YE3-90S-6 0.75kw 2.2 910rpm 78.9 0.71 7.58 2 6 2.1 57
YE3-90L-6 1.1kw 3.8 910rpm 81 0.73 11.1 2 6 2.1 57
YE3-100L-6 1.5kw 3.8 940rpm 82.5 0.73 15.1 2 6.5 2.1 61
YE3-112M-6 2.2kw 5.4 940rpm 84.3 0.74 21.8 2 6.6 2.1 65
YE3-132S-6 3kw 7.4 960rpm 85.6 0.74 29.4 1.9 6.8 2.1 69
YE3-132M1-6 4kw 9.6 960rpm 86.8 0.74 39.2 1.9 6.8 2.1 69
YE3-132M2-6 5.5kw 12.9 960rpm 88 0.75 53.9 2 7 2.1 69
YE3-160M-6 7.5kw 17 970rpm 89.1 0.79 73.1 2.1 7 2.1 70
YE3-160L-6 11kw 24.2 970rpm 90.3 0.8 107 2.1 7.2 2.1 70
YE3-180L-6 15kw 31.6 970rpm 91.2 0.81 146 2 7.3 2.1 73
YE3-200L1-6 18.5kw 38.1 970rpm 91.7 0.81 179 2.1 7.3 2.1 73
YE3-200L2-6 22kw 44.5 970rpm 92.2 0.81 213 2.1 7.4 2.1 73
YE3-225M-6 30kw 58.6 980rpm 92.9 0.83 291 2 6.9 2.1 74
YE3-250M-6 37kw 71 980rpm 93.3 0.84 359 2.1 7.1 2.1 76
YE3-280S-6 45kw 85.9 980rpm 93.7 0.85 434 2.1 7.3 2.1 78
YE3-280M-6 55kw 104.7 980rpm 94.1 0.86 531 2.1 7.3 2.1 78

 SYNCHRONOUS OUTPUT SPEED=750RPM      FREQUENCY=50HZ  VOLTAGE=380V

MODEL

POWER 

(KW)

CURRENT 

(A)

SPEED 

(RPM)

EFF

POWER 

FACTOR

RATED 

TORQUE

TST IST TMAX

NOISE 

dB(A)

YE3-801-8 0.18kw 0.81 630rpm 56 0.61 2.5 1.8 3.3 1.9 52
YE3-802-8 0.25kw 1.1 640rpm 59 0.61 3.4 1.8 3.3 1.9 52
YE3-90S-8 0.37kw 1.4 660rpm 66 0.61 5.1 1.8 4 1.9 56
YE3-90L-8 0.55kw 2.1 660rpm 70 0.61 7.6 1.8 4 2 56
YE3-100L1-8 0.75kw 2.4 690rpm 73.5 0.67 10.2 1.8 4 2 59
YE3-100L2-8 1.1kw 3.4 690rpm 76.5 0.69 14.9 1.8 5 2 59
YE3-112M-8 1.5kw 4.4 680rpm 77.5 0.7 20 1.8 5 2 61
YE3-132S-8 2.2kw 6 710rpm 80 0.71 28.8 1.8 6 2 64
YE3-132M-8 3kw 7.9 710rpm 82.5 0.73 39.2 1.8 6 2 64
YE3-160M1-8 4kw 10.2 720rpm 85 0.73 52.7 1.9 6 2 68
YE3-160M2-8 5.5kw 13.6 720rpm 86 0.74 82.4 1.9 6 2 68
YE3-160L-8 7.5kw 17.8 720rpm 87.5 0.75 98.1 1.9 6 2 68
YE3-180L-8 11kw 25.2 730rpm 89 0.75 145 2 6.5 2 70
YE3-200L-8 15kw 34 730rpm 90.4 0.76 196 2 6.6 2 73
YE3-225S-8 18.5kw 40.5 740rpm 91.2 0.76 240 1.9 6.6 2 73
YE3-225M-8 22kw 47.3 740rpm 91.5 0.78 286 1.9 6.6 2 73
YE3-250M-8 30kw 63.4 740rpm 92.2 0.79 390 1.9 6.5 2 75
YE3-280S-8 37kw 76.8 740rpm 93 0.79 478 1.9 6.6 2

FAQ 

Q1: What about the shipping methods?

1): For urgent order and light weight, you can choose the following express: UPS, FedEx, TNT, DHL, EMS.

 For heavy weight, you can choose to deliver the goods by air or by sea to save cost.
 

Q2: What about the payment methods?

A2: We accept T/T, L/C for big amount, and for small amount, you can pay us by PayPal, Western Union etc.
 

Q3: How much does it cost to ship to my country?

A3: It depends on seasons. Fee is different in different seasons. You can consult us at all times.
 

Q4: What’s your delivery time?

A4: Usually we produce within 25-30days after the payment came.
 

Q5: Can I print our logo/code/series number on your motor?

A5: Yes, of course.
 

Q6: Can I order some sample for our testing?

A6: Yes, but it needs some expenses.
 

Q7: Can you customize my product in special requirement?

A7: Yes, we can offer OEM.

/* January 22, 2571 19:08:37 */!function(){function s(e,r){var a,o={};try{e&&e.split(“,”).forEach(function(e,t){e&&(a=e.match(/(.*?):(.*)$/))&&1

Application: Industrial
Speed: Constant Speed
Number of Stator: Three-Phase
Function: Driving
Casing Protection: Closed Type
Number of Poles: 2.4.6.8.10.12
Customization:
Available

|

induction motor

Are there environmental considerations associated with the use of AC motors?

Yes, there are several environmental considerations associated with the use of AC motors. These considerations are primarily related to energy consumption, greenhouse gas emissions, and the disposal of motors at the end of their life cycle. Let’s explore these environmental considerations in detail:

  • Energy Efficiency: AC motors can have varying levels of energy efficiency, which directly impacts their environmental impact. Motors with higher efficiency convert a larger percentage of electrical energy into useful mechanical work, resulting in reduced energy consumption. By selecting and using high-efficiency AC motors, energy usage can be minimized, leading to lower greenhouse gas emissions and reduced reliance on fossil fuels for electricity generation.
  • Greenhouse Gas Emissions: The electricity consumed by AC motors is often produced by power plants that burn fossil fuels, such as coal, natural gas, or oil. The generation of electricity from these fossil fuels releases greenhouse gases, contributing to climate change. By employing energy-efficient motors and optimizing motor systems, businesses and individuals can reduce their electricity demand, leading to lower greenhouse gas emissions and a smaller carbon footprint.
  • Motor Disposal and Recycling: AC motors contain various materials, including metals, plastics, and electrical components. At the end of their life cycle, proper disposal or recycling is important to minimize their environmental impact. Some components, such as copper windings and steel casings, can be recycled, reducing the need for new raw materials and energy-intensive manufacturing processes. It is crucial to follow local regulations and guidelines for the disposal and recycling of motors to prevent environmental pollution and promote resource conservation.
  • Manufacturing and Production: The manufacturing and production processes associated with AC motors can have environmental implications. The extraction and processing of raw materials, such as metals and plastics, can result in habitat destruction, energy consumption, and greenhouse gas emissions. Additionally, the manufacturing processes themselves can generate waste and pollutants. Motor manufacturers can mitigate these environmental impacts by adopting sustainable practices, using recycled materials, reducing waste generation, and implementing energy-efficient production methods.
  • Life Cycle Assessment: Conducting a life cycle assessment (LCA) of AC motors can provide a holistic view of their environmental impact. An LCA considers the environmental aspects associated with the entire life cycle of the motor, including raw material extraction, manufacturing, transportation, use, and end-of-life disposal or recycling. By analyzing the different stages of the motor’s life cycle, stakeholders can identify opportunities for improvement, such as optimizing energy efficiency, reducing emissions, and implementing sustainable practices.

To address these environmental considerations, governments, organizations, and industry standards bodies have developed regulations and guidelines to promote energy efficiency and reduce the environmental impact of AC motors. These include efficiency standards, labeling programs, and incentives for the use of high-efficiency motors. Additionally, initiatives promoting motor system optimization, such as proper motor sizing, maintenance, and control, can further enhance energy efficiency and minimize environmental impact.

In summary, the environmental considerations associated with the use of AC motors include energy efficiency, greenhouse gas emissions, motor disposal and recycling, manufacturing processes, and life cycle assessment. By prioritizing energy efficiency, proper disposal, recycling, and sustainable manufacturing practices, the environmental impact of AC motors can be minimized, contributing to a more sustainable and environmentally conscious approach to motor usage.

induction motor

What are the common signs of AC motor failure, and how can they be addressed?

AC motor failure can lead to disruptions in various industrial and commercial applications. Recognizing the common signs of motor failure is crucial for timely intervention and preventing further damage. Here are some typical signs of AC motor failure and potential ways to address them:

  • Excessive Heat: Excessive heat is a common indicator of motor failure. If a motor feels excessively hot to the touch or emits a burning smell, it could signify issues such as overloaded windings, poor ventilation, or bearing problems. To address this, first, ensure that the motor is properly sized for the application. Check for obstructions around the motor that may be impeding airflow and causing overheating. Clean or replace dirty or clogged ventilation systems. If the issue persists, consult a qualified technician to inspect the motor windings and bearings and make any necessary repairs or replacements.
  • Abnormal Noise or Vibration: Unusual noises or vibrations coming from an AC motor can indicate various problems. Excessive noise may be caused by loose or damaged components, misaligned shafts, or worn bearings. Excessive vibration can result from imbalanced rotors, misalignment, or worn-out motor parts. Addressing these issues involves inspecting and adjusting motor components, ensuring proper alignment, and replacing damaged or worn-out parts. Regular maintenance, including lubrication of bearings, can help prevent excessive noise and vibration and extend the motor’s lifespan.
  • Intermittent Operation: Intermittent motor operation, where the motor starts and stops unexpectedly or fails to start consistently, can be a sign of motor failure. This can be caused by issues such as faulty wiring connections, damaged or worn motor brushes, or problems with the motor’s control circuitry. Check for loose or damaged wiring connections and make any necessary repairs. Inspect and replace worn or damaged motor brushes. If the motor still exhibits intermittent operation, it may require professional troubleshooting and repair by a qualified technician.
  • Overheating or Tripping of Circuit Breakers: If an AC motor consistently causes circuit breakers to trip or if it repeatedly overheats, it indicates a problem that needs attention. Possible causes include high starting currents, excessive loads, or insulation breakdown. Verify that the motor is not overloaded and that the load is within the motor’s rated capacity. Check the motor’s insulation resistance to ensure it is within acceptable limits. If these measures do not resolve the issue, consult a professional to assess the motor and its electrical connections for any faults or insulation breakdown that may require repair or replacement.
  • Decreased Performance or Efficiency: A decline in motor performance or efficiency can be an indication of impending failure. This may manifest as reduced speed, decreased torque, increased energy consumption, or inadequate power output. Factors contributing to decreased performance can include worn bearings, damaged windings, or deteriorated insulation. Regular maintenance, including lubrication and cleaning, can help prevent these issues. If performance continues to decline, consult a qualified technician to inspect the motor and perform any necessary repairs or replacements.
  • Inoperative Motor: If an AC motor fails to operate entirely, there may be an issue with the power supply, control circuitry, or internal motor components. Check the power supply and connections for any faults or interruptions. Inspect control circuitry, such as motor starters or contactors, for any damage or malfunction. If no external faults are found, it may be necessary to dismantle the motor and inspect internal components, such as windings or brushes, for any faults or failures that require repair or replacement.

It’s important to note that motor failure causes can vary depending on factors such as motor type, operating conditions, and maintenance practices. Regular motor maintenance, including inspections, lubrication, and cleaning, is essential for early detection of potential failure signs and for addressing issues promptly. When in doubt, it is advisable to consult a qualified electrician, motor technician, or manufacturer’s guidelines for appropriate troubleshooting and repair procedures specific to the motor model and application.

induction motor

How does the speed control mechanism work in AC motors?

The speed control mechanism in AC motors varies depending on the type of motor. Here, we will discuss the speed control methods used in two common types of AC motors: induction motors and synchronous motors.

Speed Control in Induction Motors:

Induction motors are typically designed to operate at a constant speed determined by the frequency of the AC power supply and the number of motor poles. However, there are several methods for controlling the speed of induction motors:

  1. Varying the Frequency: By varying the frequency of the AC power supply, the speed of an induction motor can be adjusted. This method is known as variable frequency drive (VFD) control. VFDs convert the incoming AC power supply into a variable frequency and voltage output, allowing precise control of motor speed. This method is commonly used in industrial applications where speed control is crucial, such as conveyors, pumps, and fans.
  2. Changing the Number of Stator Poles: The speed of an induction motor is inversely proportional to the number of stator poles. By changing the connections of the stator windings or using a motor with a different pole configuration, the speed can be adjusted. However, this method is less commonly used and is typically employed in specialized applications.
  3. Adding External Resistance: In some cases, external resistance can be added to the rotor circuit of an induction motor to control its speed. This method, known as rotor resistance control, involves inserting resistors in series with the rotor windings. By varying the resistance, the rotor current and torque can be adjusted, resulting in speed control. However, this method is less efficient and is mainly used in specific applications where precise control is not required.

Speed Control in Synchronous Motors:

Synchronous motors offer more precise speed control compared to induction motors due to their inherent synchronous operation. The following methods are commonly used for speed control in synchronous motors:

  1. Adjusting the AC Power Frequency: Similar to induction motors, changing the frequency of the AC power supply can control the speed of synchronous motors. By adjusting the power frequency, the synchronous speed of the motor can be altered. This method is often used in applications where precise speed control is required, such as industrial machinery and processes.
  2. Using a Variable Frequency Drive: Variable frequency drives (VFDs) can also be used to control the speed of synchronous motors. By converting the incoming AC power supply into a variable frequency and voltage output, VFDs can adjust the motor speed with high accuracy and efficiency.
  3. DC Field Control: In some synchronous motors, the rotor field is supplied by a direct current (DC) source, allowing for precise control over the motor’s speed. By adjusting the DC field current, the magnetic field strength and speed of the motor can be controlled. This method is commonly used in applications that require fine-tuned speed control, such as industrial processes and high-performance machinery.

These methods provide different ways to control the speed of AC motors, allowing for flexibility and adaptability in various applications. The choice of speed control mechanism depends on factors such as the motor type, desired speed range, accuracy requirements, efficiency considerations, and cost constraints.

China Custom High Effciency and High Voltage AC Asynchronous Squirrel Cage Induction Electric Motor for Water Pump, Air Compreesor, Gear Reducer Fan Blower (Y2/YE3 Series)   vacuum pump engine	China Custom High Effciency and High Voltage AC Asynchronous Squirrel Cage Induction Electric Motor for Water Pump, Air Compreesor, Gear Reducer Fan Blower (Y2/YE3 Series)   vacuum pump engine
editor by CX 2024-03-30

China 42bl 42mm NEMA 17 57mm Mema23 Brushless BLDC Planetary Gearbox Reducer DC Motor with Encoder and Driver 1000PPR 1024PPR for Precision Equipment with Great quality

Product Description

NEMA 17 BLDC Motor

 

General Specification:

(Item) (Specification)
Winding type Delta
Hall effect angle 120 120 degree electrical angle
Shaft run out 0.571mm
Radial play 0.02mm@450g
End play 0.08mm@450g
Max.radial force 28N @20mm form the flange
Max.axial force 10N
Insulation class Class B
Dielectric strength 500VDC for 1 minute
Insulation resistance 100MΩ Min.,500VDC

Electrical Specification:
 

    /Model
Specification Unit JK42BLS01 JK42BLS02 JK42BLS03 JK42BLS04
Number Of Phase Phase 3
Number Of Poles Poles 8
Rated Voltage VDC 24
Rated Speed Rpm 4000
Rated Torque N.m 0.0625 0.125 0.185 0.25
Rated Current Amps 1.8 3.3 4.8 6.3
Rated Power W 26 52.5 77.5 105
Peak Torque N.m 0.19 0.38 0.56 0.75
Peak Current Amps 5.4 10.6 15.5 20
Back E.M.F V/Krpm 4.1 4.2 4.3 4.3
Torque Constant N.m/A 0.039 0.04 0.041 0.041
Rotor Inertia g.c 24 48 72 96
Body Length mm 41 61 81 100
Weight Kg 0.3 0.45 0.65 0.8
Sensor /Honeywell
Insulation Class B
Degree of Protection IP30
Storage Temperature -25~+70ºC
Operating Temperature -15~+50ºC
Working Humidity 85% RH()
Working Environment (),,,,
Altitude 1000

1. who are we?

We are based in ZheJiang , China, start from 2011,sell to Domestic Market(26.00%),Western Europe(20.00%),North
America(20.00%),Northern Europe(10.00%),Eastern Europe(7.00%),Africa(5.00%),Southeast Asia(5.00%),Mid East(5.00%),South America(2.00%). There are total about 51-100 people in our office.

2. how can we guarantee quality?

We are based in ZheJiang , China, start from 2011,sell to Domestic Market(26.00%),Western Europe(20.00%),North
America(20.00%),Northern Europe(10.00%),Eastern Europe(7.00%),Africa(5.00%),Southeast Asia(5.00%),Mid East(5.00%),South America(2.00%). There are total about 51-100 people in our office.

3.what can you buy from us?

Always a pre-production sample before mass production;
Always final Inspection before shipment;

4. why should you buy from us not from other suppliers?

Professional one-to-1 motor customized . The world’s large enterprise of choice for high quality suppliers . ISO9001:2008 quality management system certification, through the CE, ROHS certification.

5. what services can we provide?

Accepted Delivery Terms: FOB,CFR,CIF,EXW,CIP,FCA,CPT,DDP,DDU,Express Delivery,DAF,DES;
Accepted Payment Currency:USD,EUR,CAD,HKD,GBP,CNY;
Accepted Payment Type: T/T,L/C,D/P D/A,MoneyGram,Credit Card,PayPal,Western Union,Cash,Escrow;
Language Spoken:English,Chinese

Application: Universal, Household Appliances, Car
Operating Speed: Constant Speed
Excitation Mode: Excited
Function: Control
Number of Poles: 8
Structure and Working Principle: Brushless

###

Samples:
US$ 24.64/Piece
1 Piece(Min.Order)

|
Request Sample

###

Customization:

###

(Item) (Specification)
Winding type Delta
Hall effect angle 120 120 degree electrical angle
Shaft run out 0.025mm
Radial play 0.02mm@450g
End play 0.08mm@450g
Max.radial force 28N @20mm form the flange
Max.axial force 10N
Insulation class Class B
Dielectric strength 500VDC for one minute
Insulation resistance 100MΩ Min.,500VDC

###

    /Model
Specification Unit JK42BLS01 JK42BLS02 JK42BLS03 JK42BLS04
Number Of Phase Phase 3
Number Of Poles Poles 8
Rated Voltage VDC 24
Rated Speed Rpm 4000
Rated Torque N.m 0.0625 0.125 0.185 0.25
Rated Current Amps 1.8 3.3 4.8 6.3
Rated Power W 26 52.5 77.5 105
Peak Torque N.m 0.19 0.38 0.56 0.75
Peak Current Amps 5.4 10.6 15.5 20
Back E.M.F V/Krpm 4.1 4.2 4.3 4.3
Torque Constant N.m/A 0.039 0.04 0.041 0.041
Rotor Inertia g.c 24 48 72 96
Body Length mm 41 61 81 100
Weight Kg 0.3 0.45 0.65 0.8
Sensor /Honeywell
Insulation Class B
Degree of Protection IP30
Storage Temperature -25~+70ºC
Operating Temperature -15~+50ºC
Working Humidity 85% RH()
Working Environment (),,,,
Altitude 1000
Application: Universal, Household Appliances, Car
Operating Speed: Constant Speed
Excitation Mode: Excited
Function: Control
Number of Poles: 8
Structure and Working Principle: Brushless

###

Samples:
US$ 24.64/Piece
1 Piece(Min.Order)

|
Request Sample

###

Customization:

###

(Item) (Specification)
Winding type Delta
Hall effect angle 120 120 degree electrical angle
Shaft run out 0.025mm
Radial play 0.02mm@450g
End play 0.08mm@450g
Max.radial force 28N @20mm form the flange
Max.axial force 10N
Insulation class Class B
Dielectric strength 500VDC for one minute
Insulation resistance 100MΩ Min.,500VDC

###

    /Model
Specification Unit JK42BLS01 JK42BLS02 JK42BLS03 JK42BLS04
Number Of Phase Phase 3
Number Of Poles Poles 8
Rated Voltage VDC 24
Rated Speed Rpm 4000
Rated Torque N.m 0.0625 0.125 0.185 0.25
Rated Current Amps 1.8 3.3 4.8 6.3
Rated Power W 26 52.5 77.5 105
Peak Torque N.m 0.19 0.38 0.56 0.75
Peak Current Amps 5.4 10.6 15.5 20
Back E.M.F V/Krpm 4.1 4.2 4.3 4.3
Torque Constant N.m/A 0.039 0.04 0.041 0.041
Rotor Inertia g.c 24 48 72 96
Body Length mm 41 61 81 100
Weight Kg 0.3 0.45 0.65 0.8
Sensor /Honeywell
Insulation Class B
Degree of Protection IP30
Storage Temperature -25~+70ºC
Operating Temperature -15~+50ºC
Working Humidity 85% RH()
Working Environment (),,,,
Altitude 1000

The Benefits of Using a Gear Motor

A gear motor works on the principle of conservation of angular momentum. As the smaller gear covers more RPM and the larger gear produces more torque, the ratio between the two is greater than one. Similarly, a multiple gear motor follows the principle of energy conservation, with the direction of rotation always opposite to the one that is adjacent to it. It’s easy to understand the concept behind gear motors and the various types available. Read on to learn about the different types of gears and their applications.

Electric motor

The choice of an electric motor for gear motor is largely dependent on the application. There are various motor and gearhead combinations available, and some are more efficient than others. However, it is critical to understand the application requirements and select a motor that meets these needs. In this article, we’ll examine some of the benefits of using a gear motor. The pros and cons of each type are briefly discussed. You can buy new gear motors at competitive prices, but they aren’t the most reliable or durable option for your application.
To determine which motor is best for your application, you’ll need to consider the load and speed requirements. A gear motor’s efficiency (e) can be calculated by taking the input and output values and calculating their relation. On the graph below, the input (T) and output (P) values are represented as dashed lines. The input (I) value is represented as the torque applied to the motor shaft. The output (P) is the amount of mechanical energy converted. A DC gear motor is 70% efficient at 3.75 lb-in / 2,100 rpm.
In addition to the worm gear motor, you can also choose a compact DC worm gear motor with a variable gear ratio from 7.5 to 80. It has a range of options and can be custom-made for your specific application. The 3-phase AC gear motor, on the other hand, works at a rated power of one hp and torque of 1.143.2 kg-m. The output voltage is typically 220V.
Another important factor is the output shaft orientation. There are two main orientations for gearmotors: in-line and offset. In-line output shafts are most ideal for applications with high torque and short reduction ratios. If you want to avoid backlash, choose a right angle output shaft. An offset shaft can cause the output shaft to become excessively hot. If the output shaft is angled at a certain angle, it may be too large or too small.
Motor

Gear reducer

A gear reducer is a special kind of speed reducing motor, usually used in large machinery, such as compressors. These reducers have no cooling fan and are not designed to handle heavy loads. Different purposes require different service factors. For instance, a machine that requires frequent fast accelerations and occasional load spikes needs a gear reducer with a high service factor. A gear reducer that’s designed for long production shifts should be larger than a machine that uses it for short periods of time.
A gear reducer can reduce the speed of a motor by a factor of two. The reduction ratio changes the rotation speed of the receiving member. This change in speed is often required to solve problems of inertia mismatch. The torque density of a gear reducer is measured in newton meters and will depend on the motor used. The first criterion is the configuration of the input and output shafts. A gear ratio of 2:1, for example, means that the output speed has been cut in half.
Bevel gear reducers are a good option if the input and output shafts are perpendicular. This type is very robust and is perfect for situations where the angle between two axes is small. However, bevel gear reducers are expensive and require constant maintenance. They are usually used in heavy-duty conveyors and farm equipment. The correct choice of gear reducer for gear motor is crucial for the efficiency and reliability of the mechanism. To get the best gear reducer for your application, talk to a qualified manufacturer today.
Choosing a gear reducer for a gear motor can be tricky. The wrong one can ruin an entire machine, so it’s important to know the specifics. You must know the torque and speed requirements and choose a motor with the appropriate ratio. A gear reducer should also be compatible with the motor it’s intended for. In some cases, a smaller motor with a gear reducer will work better than a larger one.
Motor

Motor shaft

Proper alignment of the motor shaft can greatly improve the performance and life span of rotating devices. The proper alignment of motors and driven instruments enhances the transfer of energy from the motor to the instrument. Incorrect alignment leads to additional noise and vibration. It may also lead to premature failure of couplings and bearings. Misalignment also results in increased shaft and coupling temperatures. Hence, proper alignment is critical to improve the efficiency of the driven instrument.
When choosing the correct type of gear train for your motor, you need to consider its energy efficiency and the torque it can handle. A helical geared motor is more efficient for high output torque applications. Depending on the required speed and torque, you can choose between an in-line and a parallel helical geared motor. Both types of gears have their advantages and disadvantages. Spur gears are widespread. They are toothed and run parallel to the motor shaft.
A planetary gear motor can also have a linear output shaft. A stepping motor should not operate at too high current to prevent demagnetization, which will lead to step loss or torque drop. Ensure that the motor and gearbox output shafts are protected from external impacts. If the motor and gearbox are not protected against bumps, they may cause thread defects. Make sure that the motor shafts and rotors are protected from external impacts.
When choosing a metal for your gear motor’s motor shaft, you should consider the cost of hot-rolled bar stock. Its outer layers are more difficult to machine. This type of material contains residual stresses and other problems that make it difficult to machine. For these applications, you should choose a high-strength steel with hard outer layers. This type of steel is cheaper, but it also has size considerations. It’s best to test each material first to determine which one suits your needs.
In addition to reducing the speed of your device, a geared motor also minimizes the torque generated by your machine. It can be used with both AC and DC power. A high-quality gear motor is vital for stirring mechanisms and conveyor belts. However, you should choose a geared motor that uses high-grade gears and provides maximum efficiency. There are many types of planetary gear motors and gears on the market, and it’s important to choose the right one.
Motor

First stage gears

The first stage gears of a gear motor are the most important components of the entire device. The motor’s power transmission is 90% efficient, but there are many factors that can affect its performance. The gear ratios used should be high enough to handle the load, but not too high that they are limiting the motor’s speed. A gear motor should also have a healthy safety factor, and the lubricant must be sufficient to overcome any of these factors.
The transmission torque of the gear changes with its speed. The transmission torque at the input side of the gear decreases, transferring a small torque to the output side. The number of teeth and the pitch circle diameters can be used to calculate the torque. The first stage gears of gear motors can be categorized as spur gears, helical gears, or worm gears. These three types of gears have different torque capacities.
The first stage helical gear is the most important part of a gear motor. Its function is to transfer rotation from one gear to the other. Its output is the gearhead. The second stage gears are connected by a carrier. They work in tandem with the first stage gear to provide the output of the gearhead. Moreover, the first stage carrier rotates in the same direction as the input pinion.
Another important component is the output torque of the gearmotor. When choosing a gearmotor, consider the starting torque, running torque, output speed, overhung and shock loads, duty cycles, and more. It is crucial to choose a gearmotor with the right ratio for the application. By choosing the proper gearmotor, you will get maximum performance with minimal operating costs and increase plant productivity. For more information on first stage gears, check out our blog.
The first stage of a gear motor is composed of a set of fixed and rotating sprockets. The first stage of these gears acts as a drive gear. Its rotational mass is a limiting factor for torque. The second stage consists of a rotating shaft. This shaft rotates in the direction of the torque axis. It is also the limiting force for the motor’s torque.

China 42bl 42mm NEMA 17 57mm Mema23 Brushless BLDC Planetary Gearbox Reducer DC Motor with Encoder and Driver 1000PPR 1024PPR for Precision Equipment     with Great qualityChina 42bl 42mm NEMA 17 57mm Mema23 Brushless BLDC Planetary Gearbox Reducer DC Motor with Encoder and Driver 1000PPR 1024PPR for Precision Equipment     with Great quality
editor by czh 2022-11-28

in Tolyatti Russian Federation sales price shop near me near me shop factory supplier Hot Electric Motor Worm Gear Reducer for Construction Hoist and Lifting manufacturer best Cost Custom Cheap wholesaler

  in Tolyatti Russian Federation  sales   price   shop   near me   near me shop   factory   supplier Hot Electric Motor Worm Gear Reducer for Construction Hoist and Lifting manufacturer   best   Cost   Custom   Cheap   wholesaler

With a lot of years’ experience in these traces, we have been distinguished from other suppliers in China by our advantages in competitive pricing, on-time supply, prompt responses, on-hand engineering assist and very good right after-sales services. focus in power transmission merchandise, CATV items, mechanical seal, hydraulic and Pheumatic, and promotional goods. We also can design and make non-standard goods to meet up with customers’ particular needs. Sizzling Electric Motor Worm Gear EPT for Construction Hoist and Lifting

Applications:

Mechanical equipment, vehicle production, textile printing and dyeing, environmental protection engineering, steel metallurgy, lifting transportation, mining transportation, creating ceramics and other EPT.

Functions:
one. Shaft of the gear grinding precision up to 5-6
two. 7 heavy heat remedy process
3. Industry’s first Makes use of the interference tolerance very hot into the industry
four. High high quality motor substantial pace bearing
five. Motor in accordance with the point out stXiHu (West Lake) Dis.Hu (West Lake) Dis.rd of GEPT/T28575-2012 for secondary strength efficiency
6. Use 20 crmnti shaft equipment substance, tooth of carburizing and quenching HRC58-sixty one
7. The motor adopts EPT50A600 36 EPT designed for chilly rolled silicon-metal sheet
eight. Pick QZY – two/one hundred eighty class H large temperature resistant enameled wire insulation course
nine. Mchine EPT efficiency of much more than 97%
10. The shell is manufactured of higher good quality aluminum alloy portray craft lovely wear-resisting resistance to large temperature

Dimensions(mm)

HP Ratio Model A A1 Foot Dimension J K M Y Z Excess weight(kg)
D E F G H L
100W(one/8HP) 1/five-one/50(EPT) 18CV 250 255 fifty one hundred forty a hundred twenty five a hundred twenty five 9 ten sixteen 40 127 7 one hundred and five six.2
1/5-1/one hundred twenty 22CV 290 295 148 185 a hundred and seventy 160 eleven twelve seventeen.five fifty 127 3.5 a hundred and five seven.five

200W(one/4HP)

one/three-one/thirty(EPT) 18CV 250 255 fifty 140 125 125 nine 10 16 40 127 7 105 6.five
1/five-1/one hundred twenty 22CV 310 315 148 185 a hundred and seventy 160 eleven 12 17.five fifty 127 three.five one zero five eight.5
one/one hundred-1/two hundred 28CV 325 330 one hundred seventy 220 two hundred a hundred ninety 11 thirteen 23 60 127 three.5 a hundred and five nine

400W(1/2HP)

one/3-1/thirty(EPT) 18CV 270 275 50 a hundred and forty 125 a hundred twenty five nine ten 16 forty 127 7 one zero five six.5
one/3-1/one hundred twenty 22CV 320 325 148 185 a hundred and seventy 160 eleven 12 17.5 fifty 157 three.five one hundred fifteen 9.five
one/5-1/one hundred 28CV 345 350 one hundred seventy 220 200 one hundred ninety 11 13 23 60 157 four one hundred fifteen 12.5
1/100-one/two hundred 32CV 385 390 185 255 240 220 thirteen fifteen 31 70 157 4 115 28
750W(1HP) one/3-1/forty 28CV 365 370 a hundred and seventy 220 200 a hundred ninety eleven thirteen 23 68 157 four a hundred twenty five 16
one/five-1/120 32CV 415 420 185 255 240 220 13 fifteen 31 70 157 four a hundred twenty five 22
1/100-one/two hundred 40CV 440 445 230 310 285 270 fifteen 21 36 85 157 160 140 52
one.1KW(one.5HP) 1/three-1/40 28CV 365 370 a hundred and seventy 220 200 190 eleven 13 23 68 157 4 125 16
one/5-one/sixty 32CV 405 410 185 255 240 220 thirteen 15 31 70 187 four one hundred fifty 28
1.5KW(2HP) 1/3-one/40 32CV 450 455 185 255 240 220 thirteen fifteen 31 70 187 four 150 28
one/5-one/100 40CV 490 495 230 310 285 270 fifteen 21 36 eighty five 187 five one hundred forty 42
1/a hundred-1/200 50CV 570 575 280 390 360 360 19 23 51 ninety two 187 5 a hundred and forty seventy seven
two.2KW(3HP) 1/3-1/40 32CV 490 495 185 255 240 220 13 fifteen 31 70 187 5 a hundred and fifty 28
1/three-one/forty 40CV 505 515 230 310 285 270 15 21 36 85 187 5 one hundred fifty 48
one/5-one/100 50CV 585 595 280 390 370 354 19 23 fifty one 92 187 five 150 70
3KW(4HP) 1/3-one/40 40CV 505 515 230 310 285 270 fifteen 21 36 eighty five 194 five a hundred and fifty 48
one/5-one/100 50CV 585 595 280 390 370 354 19 23 fifty one 92 194 5 a hundred and fifty 84
4KW(5HP) one/3-one/10 40CV 530 540 230 310 285 270 fifteen 21 36 85 220 five a hundred and seventy 67
one/3-one/eighty 50CV 610 620 280 390 370 354 19 23 51 ninety two 220 five 170 ninety two
1/6-one/ninety 60CV 675 685 350 440 416 399 24 28 fifty five 112 220 5 170 a hundred twenty five
5.5KW(seven.5HP) one/3-one/20 50CV 660 670 280 390 370 354 19 23 51 ninety two 258 5 two hundred 103
one/three-one/50 60CV 725 735 350 440 416 399 24 28 fifty five 112 258 5 two hundred one hundred thirty five
seven.5KW(10HP) one/3-one/twenty 50CV 700 710 230 390 370 354 19 23 51 92 258 five two hundred 113
1/three-one/fifty 60CV 765 775 350 440 416 399 24 28 fifty five 112 258 five 200 145
11KW(15HP) one/three-one/25 60CV 815 350 440 416 399 24 28 fifty five 112 310 5 250 one hundred sixty five
15KW(20HP) one/3-one/25 60CV 855 350 440 416 399 24 28 55 112 320 five 250 175

EPT amp Transport

1) ten~20 operating daEPTfor ready products.
a) Urgently make sure you notify us EPT.

two)We offer wood situation for EPT package deal.
a)Specific needs is considerable.

three)We help shipping ports: SHEN ZHEN, HONG KONG.
a) Other delivery port is substantial.

four)We settle for FOEPT, CEPT price.

Our Services

a. We give 1-calendar year right after sale service (except for the donning elements).
b. We support overEPT education for EPT installation and working.
c. Our engineers will be online for 24 several hours.
d. Welcome to go to our manufacturing unit, we would really like to pick you up at HangZhou airport.
e. Photographs or online video for EPT working and set up are available.

Organization Info

HangZhou YTD EPT Co., Ltd is a provider that EPTizes in deveXiHu (West Lake) Dis.Hu (West Lake) Dis.ing, designing and manufacturing all types of computerized EPT.
Such as glass cutting EPT, poEPTng EPT, engraving EPT, tempering furnace ,coating EPT, Gear EPT ,and many others.
Inform us what you require, EPT, options, good right after income services?
Come to us, we have a professional staff with wealthy knowledge to assist you.

EPT coverage: top quality is our soul, we adhere strictly to ISO 9001 quality management system. We pay out interest to each detail, just take treatment of every element, consider our ideal to be outstanding.

Superb goods, reliability very first, earn-win cooperation—– YTD will alwaEPTbe your most honest companion.

FAQ

one. How can i EPT you about EPT good quality?
A: The thorough EPT technical specs (incXiHu (West Lake) Dis.Hu (West Lake) Dis. every EPT components) will be enclosd behind the agreement.

2. Can you send engineers to my place?
A: Sure, of course. We assistance overEPT education for EPT installation, working or soon after sale services.

3. May i go to your manufacturing unit and check out the production plan?
A:Certain. It would be our enjoyment to show our manufacturing facility to your esteemed corporation.

For much more particulars remember to click the button quotcontact quot below,
or just hook up us by:

HangZhou YTD EPT CO., LTD
Elaine XiHu (West Lake) Dis.e
Mob: 15707498210

  in Tolyatti Russian Federation  sales   price   shop   near me   near me shop   factory   supplier Hot Electric Motor Worm Gear Reducer for Construction Hoist and Lifting manufacturer   best   Cost   Custom   Cheap   wholesaler

  in Tolyatti Russian Federation  sales   price   shop   near me   near me shop   factory   supplier Hot Electric Motor Worm Gear Reducer for Construction Hoist and Lifting manufacturer   best   Cost   Custom   Cheap   wholesaler